InitialStart-up
Priortoputtingtheintooperation,makesurethatall
thesensorlinesandthesupplycableareconnectedcorrectly.
Consultthewiringdiagramandthechapterabouttheelectric
connectionsfortheparticulartypeofengine.
Untilalltheconnectionsarechecked,donotsupplythe
withvoltage.
Withadequatevoltageandcorrectlyconnectedsupply,
thebackgroundilluminationmustglow,and
thereadingsareindicatedonthe
Ifanyofthetemperaturesensorsorthepressuresensor/in
a4-strokeengine/isnotconnected,threedashes[---]will
showonthedisplayinsteadofthemeasuredv alue.
FLY
FLY
FLY
dat
dat
dat .
c
c
Reactionatstart
Afterconnectingtheunitonpower,itwillperformanautotest.
Withnoerrorsdetected,thelogoshowsonthedisplay.
First,thedisplaywillshowthelogo,thenthedateandtime
inUTC.
Thenthefirmwareversionandtheunitsoftemperature(°C/°F)
andpressure(Bar/PSI)areshown.Atshowingthefirmware
version,thealarmoutputisactivatedfor1second.
Ifthemessage"SERVICE"isshownafterthedateandtime,
itmeansthatoneofthemeasuredquantitieshasbeenexceeded.
Afterpushingthebuttononthepanelortheexternalbutton
connectedtothepin7onthebacksideoftheinstrument,
thewillshowyouwhichquantityhasbeenexceeded.
ftheinformationonthedateandtimeis
incorrectorifthereis"Err"insteadofthe
month,itmeansthattheinternalbatterydoes
nothavesufficientcapacity.Inthiscase,
contactaservice,wherethebatterywillbe
replaced.